Family owned since 1987

+612 9625 7744

Type 2S AS1972

Additional information

Description

TEXT

TYPE 2S MINING CABLE
AS/NZS 1972:2006 Cables
APPLICATION
These individually copper screened cables are used for wiring of machines or between machines and
equipment where a rubber cable is desired. These cables are also used for longwall lighting circuits, and may
contain pilot and control cores or twisted pair and screened cores.
STANDARDS
These individually copper screened cables are used for wiring of machines or between machines and
equipment where a rubber cable is desired. These cables are also used for longwall lighting circuits, and may
contain pilot and control cores or twisted pair and screened cores.
CONSTRUCTION
CONDUCTORS:
Stranded tinned annealed copper conductor.
INSULATION:
EPR.
FILLING:
Elastomer centre filler.
PILOT/CONTROL CORES:
EPR covered and composite
screened flexible stranded tinned copper conductor.
INDIVIDUAL COMPOSITE SCREEN (EARTH CONDUCTOR):
Tinned annealed copper braiding interwove with
polyester yarn.
SHEATH:
Heavy duty CPE sheath.
Number
of Core
Nominal
Conductor
Area
Strand
Size
Insulation
Thickness
Core Screen
Pilot Conductor
Nominal
Sheath
Thickness
Nominal
Overall
Diameter
Nominal
Strand
Weight
Strand
Size
Area of
Screen
Number
of Pilots
Strand
Size
Thickness
of
Covering
mm²
No/mm
mm
mm
mm²
No/mm
mm
mm
mm
kg/100m
Type 2S 1.1/1kV Individually Screened
3
10
77/0.40
1.2
0.2
7.9
3
-
-
1.8
22.1
69
4
10
77/0.40
1.2
0.2
7.9
4
-
-
1.8
23.0
93
2
16
126/0.40
1.2
0.2
9.0
2
-
-
1.8
22.0
81
3
16
126/0.40
1.2
0.2
9.0
3
-
-
1.8
23.4
100
4
16
126/0.40
1.2
0.2
9.0
4
-
-
1.8
26.8
135
3
10
77/0.40
1.2
0.2
7.9
3
30/0.20
1.0
1.8
22.5
87
2
16
126/0.40
1.2
0.2
9.0
2
30/0.20
1.0
1.8
22.7
88
3
16
126/0.40
1.2
0.2
9.0
3
30/0.20
1.0
1.8
27.7
130
3
25
209/0.40
1.4
0.2
11.3
3
30/0.20
1.0
1.8
29.2
165
3
35
285/0.40
1.4
0.2
12.4
3
30/0.20
1.0
1.8
31.6
200
3
50
380/0.40
1.6
0.25
17.5
3
30/0.20
1.0
1.9
36.1
260
Type 2S 1.1/1kV Individually and Collectively Screened
30
1.5
30/0.25
1.0
0.3
14.0
-
-
-
1.9
32.6
170
Type 2S 3.3/3.3Kv Individually Screened
3
10
77/0.40
3.0
0.2
11.3
3
30/0.25
1.0
1.8
28.9
130
3
16
126/0.40
3.0
0.2
12.4
3
30/0.25
1.0
1.8
31.3
160
3
25
209/0.40
3.0
0.2
13.6
3
30/0.25
1.0
1.9
34.8
210
3
35
285/0.40
3.0
0.2
15.3
3
30/0.25
1.0
2.0
37.8
250
3
50
380/0.40
3.0
0.2
17.0
3
30/0.25
1.0
2.1
41.3
305
3
70
203/0.67
3.0
0.3
30.5
3
30/0.25
1.0
2.2
46.8
415
3
95
259/0.67
3.0
0.3
30.5
3
30/0.25
1.0
2.3
49.6
490
3
120
336/0.67
3.0
0.4
47.5
3
30/0.25
1.0
2.5
55.0
620
ti
............................................................................................................
ti
fi
fl
ti
Heavy Duty CPE Sheat
Stranded Tinned Copper Conducto
Pilot/Control Core
Individual Composite Screen
EPR Insulation
Elastomer Centre Fille
Stranded Tinned Copper Conductor
EPR Insulation
Elastomer Centre Filler
Individual Composite Screen
Pilot/Control Cores
Heavy Duty CPE Sheath
www.hastingselectrical.com.au
Ph: 02 9625 7744

HASTINGS

ELECTRICAL PTY LTD