Family owned since 1987

+612 9625 7744

Instrumentation Triads

Additional information

Description

TEXT

APPLICATION

Used in data processing and process control. Suitable for fixed installations in damp locations and open spaces.

The electrostatic screen protects against outer interference fields.

DESIGN

Instrumentation cable consisting of bare copper conductors, black & white twisted pairs or black, white & red

twisted triples with continuous number sequence.

Cables are manufactured strictly in accordance of UL as well as relevant Australian Standards.

LSZH (Low Smoke Zero Halogen) available upon request.

VOLTAGE RATING

Rated Voltage

Max. 300V a.c

Nominal Voltage

A.C/D.C 110/150V

Test Voltage

In process spark test – 4500V and AC withstand voltage test – 1500V

TECHNICAL DATA

0.5mm                                          1.5mm

Maximum Capacitance

Conductor              to              Conductor                                          145pF/m                            200pF/m

Conductor              to              Screen                                          240pF/m                            300pF/m

Maximum Conductor Resistance @ 20 C

38.4Ω/km

13.6Ω/km

Insulation Resistance @ 20 C

40MΩ/km

140MΩ/km

Cross Talk Attentuation Between Pairs @ 1kHz

300Ω

150Ω

Inductance              @              1kHz                                                        1.00mH/km                            0.95mH/km

L/R Ratio @ 1kHz

13.7μH/Ω

36.5μH/Ω

OPERATING TEMPERATURE

Minimum continuous operating temperature

-25

°

C

Maximum continuous operating temperature

75

°

C

Maximum conductor operating temperature

90

°

C

Minimum short circuit temperature

160

°

C (for 5 sec)

BENDING RADII

The following minimum bending radius should be observed to ensure operating reliability

Unarmoured:

9 x cable outer diameter (during installation)

6 x cable outer diameter (after installation)

Armoured:

18 x cable outer diameter (during installation)

12 x cable outer diameter (after installation)

TENSILE STRENGTH

Cable maximum pulling tension (approximate) is limited to 65-70 N/mm² of the total cross-sectional area of

conductor.

Example:

3pairs  1.5  total cross sectional area   3x 2x1.5=9mm

²

9mm

²

x 70Nmm

²

=630N (0.63kn)

For pulling by armour, the pulling tension should be limited to 130 N/mm

²

of the total cross-sectional of steel

wire.

INSTRUMENTATION CABLE-TRIADS

 

 

INSTRUMENTATION CABLE

Overall Screened Triad

0.5mm²

Part No

Triples

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Nom. Overall

Diameter (mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

0.5MM1TR

1

7/0.30

0.4

5.2

38.4

36

0.5MM2TR

2

7/0.30

0.4

7.8

38.4

70

0.5MM3TR

3

7/0.30

0.4

8.9

38.4

84

0.5MM4TR

4

7/0.30

0.4

9.2

38.4

120

0.5MM6TR

6

7/0.30

0.4

11.3

38.4

179

0.5MM8TR

8

7/0.30

0.4

12.2

38.4

225

0.5MM10TR

10

7/0.30

0.4

14.6

38.4

290

0.5MM12TR

12

7/0.30

0.4

15.5

38.4

348

0.5MM16TR

16

7/0.30

0.4

17.1

38.4

442

0.5MM20TR

20

7/0.30

0.4

18.6

38.4

543

0.5MM24TR

24

7/0.30

0.4

21.3

38.4

653

0.5MM36TR

36

7/0.30

0.4

24.4

38.4

936

1.5mm²

Part No

Triples

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Nom. Overall

Diameter (mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

1.5MM1TR

1

7/0.50

0.4

6.5

13.6

67

1.5MM2TR

2

7/0.50

0.4

10

13.6

135

1.5MM3TR

3

7/0.50

0.4

10.9

13.6

201

1.5MM4TR

4

7/0.50

0.4

11.8

13.6

237

1.5MM6TR

6

7/0.50

0.4

14.5

13.6

352

1.5MM8TR

8

7/0.50

0.4

16

13.6

463

1.5MM10TR

10

7/0.50

0.4

19.1

13.6

589

1.5MM12TR

12

7/0.50

0.4

19.7

13.6

683

1.5MM16TR

16

7/0.50

0.4

22.5

13.6

946

1.5MM20TR

20

7/0.50

0.4

24.3

13.6

1153

1.5MM24TR

24

7/0.50

0.4

27.7

13.6

1374

1.5MM36TR

36

7/0.50

0.4

32

13.6

2014

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

V90 Insulated

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

V90 Insulated Black outer sheath (Blue Intrinsically Safe option avail)

INSTRUMENTATION CABLE

Overall Screened SWA Triad

0.5mm

²

Part No

Triples

Conductor

No/Dia

(mm)

Insulation

thickness

(mm)

Overall

diameter

over

bedding

(mm)

Steel wire

Amour

diameter

(mm)

Overall

diameter

over

armour

(mm)

Overall

Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate

weight (kg/

km)

0.5MM1TRSWA

1

7/0.30

0.4

5.9

0.9

7.7

10.6

38.4

239

0.5MM2TRSWA

2

7/0.30

0.4

8.1

0.9

9.9

12.8

38.4

329

0.5MM3TRSWA

3

7/0.30

0.4

8.5

0.9

10.3

13.2

38.4

356

0.5MM4TRSWA

4

7/0.30

0.4

9.3

0.9

10.5

14

38.4

399

0.5MM6TRSWA

6

7/0.30

0.4

11.4

0.9

11.1

16.3

38.4

517

0.5MM8TRSWA

8

7/0.30

0.4

12.3

0.9

13.2

17.2

38.4

585

0.5MM10TRSWA

10

7/0.30

0.4

14.3

0.9

14.1

19.4

38.4

697

0.5MM12TRSWA

12

7/0.30

0.4

14.8

0.9

16.1

20.3

38.4

770

0.5MM16TRSWA

16

7/0.30

0.4

16.4

0.9

18.2

21.9

38.4

903

0.5MM20TRSWA

20

7/0.30

0.4

17.7

0.9

19.5

23.2

38.4

1028

0.5MM24TRSWA

24

7/0.30

0.4

20.2

1.25

22.7

26.4

38.4

1363

0.5MM36TRSWA

36

7/0.30

0.4

23.5

1.25

26

30.1

38.4

1785

1.5mm

²

Part No

Triples

Conductor

No/Dia

(mm)

Insulation

thickness

(mm)

Overall

diameter

over

bedding

(mm)

Steel wire

Amour

diameter

(mm)

Overall

diameter

over

armour

(mm)

Overall

Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate

weight (kg/

km)

1.5MM1TRSWA

1

7/0.50

0.4

7

0.9

8.8

11.7

13.6

303

1.5MM2TRSWA

2

7/0.50

0.4

9.9

0.9

11.7

14.6

13.6

437

1.5MM3TRSWA

3

7/0.50

0.4

10.9

0.9

12.8

15.8

13.6

520

1.5MM4TRSWA

4

7/0.50

0.4

11.9

0.9

13.7

16.8

13.6

609

1.5MM6TRSWA

6

7/0.50

0.4

14.2

0.9

16

19.3

13.6

784

1.5MM8TRSWA

8

7/0.50

0.4

15.3

0.9

17.1

20.8

13.6

935

1.5MM10TRSWA

10

7/0.50

0.4

18

1.25

20.5

24.2

13.6

1119

1.5MM12TRSWA

12

7/0.50

0.4

18.6

1.25

21.1

24.8

13.6

1401

1.5MM16TRSWA

16

7/0.50

0.4

20.7

1.25

23.2

27

13.6

1680

1.5MM20TRSWA

20

7/0.50

0.4

22.9

1.25

25.4

29.3

13.6

1986

1.5MM24TRSWA

24

7/0.50

0.4

26.4

1.6

29.6

33.7

13.6

2577

1.5MM36TRSWA

36

7/0.50

0.4

30.2

1.6

33.4

37.9

13.6

3379

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

V90 Insulated

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

Black flame retardant HX90 inner sheath to UL style 2464

Steel wire armour

V90 Black outer sheath (Blue Intrinsically Safe option avail)

INSTRUMENTATION CABLE

Individual & Overall Screened Triad

0.5mm²

Part No

Triples

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Nom. Overall

Diameter (mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

0.5MM2TRES

2

7/0.30

0.4

8.3

38.4

78

0.5MM3TRES

3

7/0.30

0.4

8.8

38.4

103

0.5MM4TRES

4

7/0.30

0.4

9.8

38.4

135

0.5MM6TRES

6

7/0.30

0.4

12.1

38.4

201

0.5MM8TRES

8

7/0.30

0.4

13.3

38.4

259

0.5MM10TRES

10

7/0.30

0.4

15.7

38.4

326

0.5MM12TRES

12

7/0.30

0.4

16.2

38.4

377

0.5MM16TRES

16

7/0.30

0.4

18.3

38.4

498

0.5MM20TRES

20

7/0.30

0.4

19.3

38.4

599

0.5MM24TRES

24

7/0.30

0.4

23.1

38.4

748

0.5MM36TRES

36

7/0.30

0.4

26.3

38.4

1058

1.5mm²

Part No

Triples

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Nom. Overall

Diameter (mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

1.5MM2TRES

2

7/0.50

0.4

10.9

13.6

152

1.5MM3TRES

3

7/0.50

0.4

11.8

13.6

212

1.5MM4TRES

4

7/0.50

0.4

12.9

13.6

269

1.5MM6TRES

6

7/0.50

0.4

15.8

13.6

399

1.5MM8TRES

8

7/0.50

0.4

17.5

13.6

525

1.5MM10TRES

10

7/0.50

0.4

20.9

13.6

668

1.5MM12TRES

12

7/0.50

0.4

21.5

13.6

776

1.5MM16TRES

16

7/0.50

0.4

24.1

13.6

1011

1.5MM20TRES

20

7/0.50

0.4

26

13.6

1233

1.5MM24TRES

24

7/0.50

0.4

29.7

13.6

1470

1.5MM36TRES

36

7/0.50

0.4

34.4

13.6

2154

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

Flame retardant HX90 Insulation to UL style 1569

V90 Insulated

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

V90 Black outer sheath (Blue Intrinsically Safe option avail)

INSTRUMENTATION CABLE

Individual & Overall Screened SWA Triad

0.5mm

²

Part No

Triples

Conductor

No/Dia

(mm)

Insulation

thickness

(mm)

Overall

diameter

over

bedding

(mm)

Steel wire

Amour

diameter

(mm)

Overall

diameter

over

armour

(mm)

Overall

Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate

weight (kg/

km)

0.5MM2TRSWAES

2

7/0.30

0.4

8.6

0.9

10.4

13.3

38.4

344

0.5MM3TRSWAES

3

7/0.30

0.4

9.1

0.9

10.9

13.8

38.4

382

0.5MM4TRSWAES

4

7/0.30

0.4

9.9

0.9

11.7

14.6

38.4

429

0.5MM6TRSWAES

6

7/0.30

0.4

12

0.9

13.8

16.9

38.4

548

0.5MM8TRSWAES

8

7/0.30

0.4

13.2

0.9

15

18.1

38.4

635

0.5MM10TRSWAES

10

7/0.30

0.4

15.4

0.9

17.2

20.7

38.4

768

0.5MM12TRSWAES

12

7/0.30

0.4

15.9

0.9

17.7

21.9

38.4

830

0.5MM16TRSWAES

16

7/0.30

0.4

17.6

0.9

19.4

23.1

38.4

989

0.5MM20TRSWAES

20

7/0.30

0.4

19.1

0.9

20.9

25.7

38.4

1130

0.5MM24TRSWAES

24

7/0.30

0.4

21.8

1.25

24.3

29.5

38.4

1507

0.5MM36TRSWAES

36

7/0.30

0.4

25.4

1.25

27.9

34.9

38.4

1949

1.5mm

²

Part No

Triples

Conductor

No/Dia

(mm)

Insulation

thickness

(mm)

Overall

diameter

over

bedding

(mm)

Steel wire

Amour

diameter

(mm)

Overall

diameter

over

armour

(mm)

Overall

Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate

weight (kg/

km)

1.5MM2TRSWAES

2

7/0.50

0.4

10.8

0.9

12.6

15.5

13.6

463

1.5MM3TRSWAES

3

7/0.50

0.4

11.7

0.9

13.5

16.6

13.6

551

1.5MM4TRSWAES

4

7/0.50

0.4

13

0.9

14.8

17.9

13.6

646

1.5MM6TRSWAES

6

7/0.50

0.4

15.5

0.9

17.3

20.6

13.6

834

1.5MM8TRSWAES

8

7/0.50

0.4

16.8

0.9

18.6

22.3

13.6

996

1.5MM10TRSWAES

10

7/0.50

0.4

19.8

0.9

21.6

25.3

13.6

1195

1.5MM12TRSWAES

12

7/0.50

0.4

20.4

1.25

22.9

26.6

13.6

1493

1.5MM16TRSWAES

16

7/0.50

0.4

22.8

1.25

25.3

29.2

13.6

1799

1.5MM20TRSWAES

20

7/0.50

0.4

25.1

1.25

27.6

31.5

13.6

2118

1.5MM24TRSWAES

24

7/0.50

0.4

29

1.6

32.3

36.3

13.6

2748

1.5MM36TRSWAES

36

7/0.50

0.4

33.3

1.6

38.3

42.8

13.6

4356

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

V90 Insulated

Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

V90 Inner sheath

Steel wire armour

V90 Black outer sheath (Blue Intrinsically Safe option avail)

 

www.hastingselectrical.com.au
Ph: 02 9625 7744

HASTINGS

ELECTRICAL PTY LTD