Family owned since 1987

+612 9625 7744

Instrumentation Pairs

Additional information

Description

TEXT

APPLICATION

Used in data processing and process control. Suitable for fixed installations in damp locations and open spaces.

The electrostatic screen protects against outer interference fields.

DESIGN

Instrumentation cable consisting of bare copper conductors, black & white twisted pairs or black, white & red

twisted triples with continuous number sequence.

Cables are manufactured strictly in accordance of UL as well as relevant Australian Standards.

LSZH (Low Smoke Zero Halogen) available upon request.

VOLTAGE RATING

Rated Voltage

Max. 300V a.c

Nominal Voltage

A.C/D.C 110/150V

Test Voltage

In process spark test – 4500V and AC withstand voltage test – 1500V

TECHNICAL DATA

0.5mm                                          1.5mm

Maximum Capacitance

Conductor              to              Conductor                                          145pF/m                            200pF/m

Conductor              to              Screen                                          240pF/m                            300pF/m

Maximum Conductor Resistance @ 20 C

38.4Ω/km

13.6Ω/km

Insulation Resistance @ 20 C

40MΩ/km

140MΩ/km

Cross Talk Attentuation Between Pairs @ 1kHz

300Ω

150Ω

Inductance              @              1kHz                                                        1.00mH/km                            0.95mH/km

L/R Ratio @ 1kHz

13.7μH/Ω

36.5μH/Ω

OPERATING TEMPERATURE

Minimum continuous operating temperature

-25

°

C

Maximum continuous operating temperature

75

°

C

Maximum conductor operating temperature

90

°

C

Minimum short circuit temperature

160

°

C (for 5 sec)

BENDING RADII

The following minimum bending radius should be observed to ensure operating reliability

Unarmoured:

9 x cable outer diameter (during installation)

6 x cable outer diameter (after installation)

Armoured:

18 x cable outer diameter (during installation)

12 x cable outer diameter (after installation)

TENSILE STRENGTH

Cable maximum pulling tension (approximate) is limited to 65-70 N/mm² of the total cross-sectional area of

conductor.

Example:

3pairs  1.5  total cross sectional area   3x 2x1.5=9mm

²

9mm

²

x 70Nmm

²

=630N (0.63kn)

For pulling by armour, the pulling tension should be limited to 130 N/mm

²

of the total cross-sectional of steel

wire.

INSTRUMENTATION CABLE-PAIRS

Overall Screened Pairs

0.5mm²

Part No

Pairs

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Nom. Overall

Diameter (mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

0.5MM1PR

1

7/0.30

0.4

5

38.4

28

0.5MM2PR

2

7/0.30

0.4

7.3

38.4

51

0.5MM3PR

3

7/0.30

0.4

8.1

38.4

71

0.5MM4PR

4

7/0.30

0.4

8.7

38.4

86

0.5MM6PR

6

7/0.30

0.4

10.5

38.4

124

0.5MM8PR

8

7/0.30

0.4

11.7

38.4

166

0.5MM10PR

10

7/0.30

0.4

13.9

38.4

210

0.5MM12PR

12

7/0.30

0.4

14.3

38.4

239

0.5MM16PR

16

7/0.30

0.4

16.3

38.4

317

0.5MM20PR

20

7/0.30

0.4

17.9

38.4

396

0.5MM24PR

24

7/0.30

0.4

20.5

38.4

477

0.5MM36PR

36

7/0.30

0.4

23.5

38.4

675

1.5mm²

Part No

Pairs

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Overall Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

1.5MM1PR

1

7/0.50

0.4

6.1

13.6

53

1.5MM2PR

2

7/0.50

0.4

11

13.6

103

1.5MM3PR

3

7/0.50

0.4

12.2

13.6

145

1.5MM4PR

4

7/0.50

0.4

13

13.6

183

1.5MM6PR

6

7/0.50

0.4

14

13.6

266

1.5MM8PR

8

7/0.50

0.4

15.2

13.6

349

1.5MM10PR

10

7/0.50

0.4

18.2

13.6

430

1.5MM12PR

12

7/0.50

0.4

19

13.6

506

1.5MM16PR

16

7/0.50

0.4

21.3

13.6

658

1.5MM20PR

20

7/0.50

0.4

23.4

13.6

809

1.5MM24PR

24

7/0.50

0.4

27

13.6

974

1.5MM36PR

36

7/0.50

0.4

29.7

13.6

1403

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

V90 Insulated

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

V90 Black outer sheath (Blue Intrinsically Safe option avail)

Individual & Overall Screened Pairs

0.5mm²

Part No

Pairs

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Nom. Overall

Diameter (mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

0.5MM2PRES

2

7/0.30

0.4

8.8

38.4

58

0.5MM4PRES

4

7/0.30

0.4

9.3

38.4

100

0.5MM6PRES

6

7/0.30

0.4

11.3

38.4

145

0.5MM8PRES

8

7/0.30

0.4

12.6

38.4

193

0.5MM10PRES

10

7/0.30

0.4

14.9

38.4

244

0.5MM12PRES

12

7/0.30

0.4

15.4

38.4

279

0.5MM16PRES

16

7/0.30

0.4

17.5

38.4

370

0.5MM20PRES

20

7/0.30

0.4

19.3

38.4

462

0.5MM24PRES

24

7/0.30

0.4

22.1

38.4

558

0.5MM36PRES

36

7/0.30

0.4

25.3

38.4

792

1.5mm²

Part No

Pairs

Conductor

No/Dia (mm)

Insulation

thickness

(mm)

Nom. Overall

Diameter (mm)

Conductor

Resistance  @

20c Ohm/km

Approximate weight

(kg/km)

1.5MM2PRES

2

7/0.50

0.4

11.1

13.6

113

1.5MM4PRES

4

7/0.50

0.4

12.1

13.6

199

1.5MM6PRES

6

7/0.50

0.4

14.6

13.6

290

1.5MM8PRES

8

7/0.50

0.4

16.2

13.6

381

1.5MM10PRES

10

7/0.50

0.4

19

13.6

470

1.5MM12PRES

12

7/0.50

0.4

21.1

13.6

570

1.5MM16PRES

16

7/0.50

0.4

22.2

13.6

717

1.5MM20PRES

20

7/0.50

0.4

24.2

13.6

884

1.5MM24PRES

24

7/0.50

0.4

27.8

13.6

1064

1.5MM36PRES

36

7/0.50

0.4

31.9

13.6

1535

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

V90 Insulated

Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

V90 Black outer sheath (Blue Intrinsically Safe option avail)

Overall Screened SWA Pairs

0.5mm

²

Part No

Pairs

Conductor

No/Dia

(mm)

Insulation

thickness

(mm)

Overall

diameter

over

bedding

(mm)

Steel wire

Amour

diameter

(mm)

Overall

diameter

over

armour

(mm)

Overall

Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate

weight (kg/

km)

0.5MM1PRSWA

1

7/0.30

0.4

5.6

0.9

7.4

10.4

38.4

225

0.5MM2PRSWA

2

7/0.30

0.4

8.6

0.9

10.4

12.5

38.4

298

0.5MM4PRSWA

4

7/0.30

0.4

9.8

0.9

11.6

14.5

38.4

358

0.5MM6PRSWA

6

7/0.30

0.4

10.6

0.9

12.4

15.5

38.4

440

0.5MM8PRSWA

8

7/0.30

0.4

11.4

0.9

13.2

16.7

38.4

507

0.5MM10PRSWA

10

7/0.30

0.4

13.3

0.9

15.1

18.7

38.4

592

0.5MM12PRSWA

12

7/0.30

0.4

13.7

0.9

15.5

19.1

38.4

632

0.5MM16PRSWA

16

7/0.30

0.4

15.4

0.9

17.2

21.3

38.4

763

0.5MM20PRSWA

20

7/0.30

0.4

16.6

1.25

19.1

23.2

38.4

1006

0.5MM24PRSWA

24

7/0.30

0.4

18.9

1.25

21.4

25.6

38.4

1150

0.5MM36PRSWA

36

7/0.30

0.4

21.8

1.25

24.3

28.8

38.4

1449

1.5mm

²

Part No

Pairs

Conductor

No/Dia

(mm)

Insulation

thickness

(mm)

Overall

diameter

over

bedding

(mm)

Steel wire

Amour

diameter

(mm)

Overall

diameter

over

armour

(mm)

Overall

Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate

weight (kg/

km)

1.5MM1PRSWA

1

7/0.50

0.4

6.7

0.9

8.5

11.5

13.6

278

1.5MM2PRSWA

2

7/0.50

0.4

10.4

0.9

12.2

15.3

13.6

390

1.5MM4PRSWA

4

7/0.50

0.4

11.9

0.9

13.7

17.8

13.6

498

1.5MM6PRSWA

6

7/0.50

0.4

13.2

0.9

15

18.3

13.6

651

1.5MM8PRSWA

8

7/0.50

0.4

14.2

0.9

16

19.2

13.6

749

1.5MM10PRSWA

10

7/0.50

0.4

16.7

1.25

19.2

22.5

13.6

1043

1.5MM12PRSWA

12

7/0.50

0.4

17.3

1.25

19.8

23.8

13.6

1150

1.5MM16PRSWA

16

7/0.50

0.4

19.4

1.25

21.9

26

13.6

1370

1.5MM20PRSWA

20

7/0.50

0.4

21.3

1.25

23.8

28.1

13.6

1591

1.5MM24PRSWA

24

7/0.50

0.4

24.3

1.6

26.8

32.1

13.6

1856

1.5MM36PRSWA

36

7/0.50

0.4

27.9

1.6

31.1

35

13.6

2645

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

V90 Insulated

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

V90 Inner Sheath

Steel wire armour

Black outer sheath (Blue Intrinsically Safe option avail)

0.5MM2PRSWAES

2

7/0.30

0.4

9.2

0.9

11

14

38.4

318

0.5MM4PRSWAES

4

7/0.30

0.4

9.9

0.9

11.7

14.8

38.4

387

0.5MM6PRSWAES

6

7/0.30

0.4

11.3

0.9

13.1

16.3

38.4

480

0.5MM8PRSWAES

8

7/0.30

0.4

12.2

0.9

14

17.6

38.4

555

0.5MM10PRSWAES

10

7/0.30

0.4

14.3

0.9

16.1

19.7

38.4

651

0.5MM12PRSWAES

12

7/0.30

0.4

14.8

0.9

16.6

20.2

38.4

699

0.5MM16PRSWAES

16

7/0.30

0.4

16.6

0.9

19.1

22.8

38.4

995

0.5MM20PRSWAES

20

7/0.30

0.4

17.9

1.25

20.4

24.6

38.4

1113

0.5MM24PRSWAES

24

7/0.30

0.4

20.5

1.25

23

27.2

38.4

1277

0.5MM36PRSWAES

36

7/0.30

0.4

23.6

1.25

26.1

30.6

38.4

1622

1.5mm

²

Part No.

Pairs

Conductor

No/Dia

(mm)

Insulation

thickness

(mm)

Overall

diameter

over

bedding

(mm)

Steel wire

Amour

diameter

(mm)

Overall

diameter

over

armour

(mm)

Overall

Diameter

(mm)

Conductor

Resistance  @

20c Ohm/km

Approximate

weight (kg/

km)

1.5MM2PRSWAES

2

7/0.50

0.4

11

0.9

12.8

15.9

13.6

413

1.5MM4PRSWAES

4

7/0.50

0.4

12.1

0.9

13.9

17

13.6

532

1.5MM6PRSWAES

6

7/0.50

0.4

14.1

0.9

15.9

18.6

13.6

699

1.5MM8PRSWAES

8

7/0.50

0.4

15.2

0.9

17

20.2

13.6

805

1.5MM10PRSWAES

10

7/0.50

0.4

18.2

1.25

20.7

24

13.6

1136

1.5MM12PRSWAES

12

7/0.50

0.4

18.8

1.25

21.3

25.1

13.6

1252

1.5MM16PRSWAES

16

7/0.50

0.4

20.9

1.25

23.4

27.5

13.6

1477

1.5MM20PRSWAES

20

7/0.50

0.4

22.9

1.25

25.4

29.7

13.6

1718

1.5MM24PRSWAES

24

7/0.50

0.4

26.2

1.6

29.4

34

13.6

2236

1.5MM36PRSWAES

36

7/0.50

0.4

30.1

1.6

33.3

38.1

13.6

2864

INSTRUMENTATION  CABLE

Individual & Overall Screened SWA Pairs

Intrinsically Safe version – add BLUE to part number

Intrinsically Safe version – add BLUE to part number

CONSTRUCTION CONSISTING OF:

Bare copper conductors to AS1125

V90 Insulated

Individual screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

Overall screen of Al/polyester tape with tinned copper 7/0.20 stranded drain wire

V90 Inner Sheath

Steel wire armour

V90 Black outer sheath (Blue Intrinsically Safe option avail)

 

www.hastingselectrical.com.au
Ph: 02 9625 7744

HASTINGS

ELECTRICAL PTY LTD